DT360Xi
Underwater Hardware Specifications
Frequency
2.25 MHz
Transducer Beam Width
(nominal)
Horizontal: 360°
Vertical: 0.7°
Effective Beam Widths
Narrow: 0.75°
Medium: 1.5°
Wide: 3°
Number of Beams
360, 720, 1440
Data is acquired at full resolution every shot: processing the data for screen display on a PC can slow the system at highest number of beams. 360 beam mode is recommended for real time data acquisition. The data can then be played back at highest resolution (1440 beam).
Data Points
500 or 1000
Range Resolution
1/500 or 1/1000 of range
Min. Detectable Range
0.25 m
Max. Operating Depth
1000 m
Frame Rate
Up to 20 fps
Interface to PC
Ethernet (100 Mbps) using TCP/IP
Max. Cable Length
100 m on CAT5e
(Longer cable runs possible with additional hardware)
Connector
End mounted, 8 conductor, wet mateable (Subconn MCBH8M-SS)
Power Supply
24 V Nominal, (22 – 32 VDC) at less than 25 Watts
Dimensions
See Drawing
Weight in Air
~12 lbs (~5.4 kg)
Weight in Water
TBA
Materials
6061-T6 Aluminum, PVC, Epoxy, Stainless Steel connector
Finish
Hard Anodize
Software Specifications
DT360Xi.exe
Windows™ Operating System
Windows™ XP, Vista, 7, 8, 10
Display Modes
Polar, Beam Test
Range Scales
0.5 m, 1 m, 2 m, 3 m, 4 m, 5 m, 6 m, 8 m, 10 m
Pulse Width
Automatic with manual multiplier
Manual Gain Control
0 to 20 dB
File Format
Raw Data: (filename).IGX
Beam: (filename).B96
Point: (filename).P96
Recommended Minimum Computer Requirements
2 GHz Pentium 4
256 MB RAM
20 GB Hard Disk
1024 x 768 screen resolution
Ordering Information
1000 m Unit
965-000-301
2.25 MHz
Option (included) -003
Xi
Option (included) -055